Skip to content Skip to footer

Fit-Cor 3004 • Scale and Corrosion inhibitor

Fit-Cor 3004 is a liquid cooling water scale and corrosion inhibitor that is specifically designed for use in open circuit evaporative cooling systems and air conditioning plant that operate under hard water conditions. This product is highly effective and non-volatile, offering excellent performance in preventing scale buildup and corrosion.

Fit-Cor 3004 is formulated to work in conjunction with Accepta biocide treatments to control the type of bacteria that can be a source of Legionella species, providing critical performance in this regard. Additionally, this product is a multi-functional alkaline blend that includes an organic corrosion inhibitor, a threshold deposit controller, and a sludge conditioner. It is capable of providing protection to multi- metal systems without the need for additional specific corrosion inhibitors.

Technical Data Sheet Safety Data Sheet

Description

Fit-Cor 3004 is a liquid cooling water scale and corrosion inhibitor that is specifically designed for use in open circuit evaporative cooling systems and air conditioning plant that operate under hard water conditions. This product is highly effective and non-volatile, offering excellent performance in preventing scale buildup and corrosion.

Fit-Cor 3004 is formulated to work in conjunction with Accepta biocide treatments to control the type of bacteria that can be a source of Legionella species, providing critical performance in this regard. Additionally, this product is a multi-functional alkaline blend that includes an organic corrosion inhibitor, a threshold deposit controller, and a sludge conditioner. It is capable of providing protection to multi- metal systems without the need for additional specific corrosion inhibitors.

 

Features :

  • Suitable for systems with extended holding times and high water temperatures. Effectively prevents corrosion and scale buildup in open cooling towers.
  • No need for pH control.
  • Includes synthetic dispersants to manage suspended solids.
  • Easy to apply and manage.
  • Does not encourage bacterial growth.
  • Offers protection to multi- metal systems without requiring additional corrosion inhibitors.
  • Provides protection over an extended range of pH, temperature, and raw water hardness.
  • Does not contain any controversial heavy metals or phosphates.

 

Specifications :

  • Appearance : Clear, Colourless Liquid
  • Specific Gravity : 1.12 – 1.18
  • Solubility in Water : Complete
  • pH@25oC : 1.0 Approx
  • Flash Point : Non-flammable

 

Application :

Fit-Cor 3004 is normally fed to supply a corrosion & scale protection for open evaporative cooling towers. Fit-Cor 3004 contains a blend of organic inhibitors synthetic dispersant with a high performance to deal with a high levels of suspended solids in the make up water. It can maintain the system to keep high heat transfer efficiency. Fit-Cor 3004 can be dosed by a separate dosing pump on the make up feed line to give the needed reserve of oregano phosphates inside the cooling water. The correct treatment level depends on operating conditions such as pH, cycles of concentration, temperature and the bleed rate.

 

Packaging :

Packaged in 28 kg and 224 kg plastic drums.

 

Safety & Handling :

it-Cor 3004 is strong irritant to skin and eyes. Thus; it should be handled carefully. The wearing of gloves and goggles is recommended.

 

Technical support & Advice :

Nikor water technologies work closely with a diverse range of global organisations, intelligently combining advanced treatment technologies with practical solutions to resolve complex issues. If you have a project you would like to discuss, or you require technical support and assistance, or if you simply have a question about fedor Fit- Biocide 981 inhibitors please contact one of our specialist advisors on [email protected]